The profession works with checklists, external validation, behavioural rules, and post-market surveillance, and these practices follow measurement from the model to the place of use. The weakest link is the checking that takes place after deployment, in the hospital.

Edited by Zoltán Varga · 2026-11-21 · 11 min read

How this was made: this essay was written by the author's own research and analysis system from the cited sources; Zoltán Varga edited the topic, structure and final text. The cited works are the source of its factual claims.

Evidence in Medicine · 4/4. part

The existence of a reporting guideline says little about adherence to it, yet in debates on medical AI practices, the guideline itself is often cited as evidence of good practice. The profession currently works with an extensive toolkit: checklists for reporting trials, validation rules for predictive models, behavioural requirements for decision support, and surveillance obligations for devices placed on the market. These methods all answer the same question that connected the earlier parts of the series: where does the error arise, and who notices it?

The benchmarks of the earlier parts (the location of error, the addressee of the evidence and the decision of the measuring institution) become daily work in the practices. For the practices, therefore, the subject includes not only what the method prescribes but also what measurement shows about adherence to it.

Reporting of randomised trials expanded to cover AI

The randomised trial is the benchmark for the effect of use and stands at the top of the ladder discussed in the second part. In How to Read a Paper, Trisha Greenhalgh describes how, in 1996, an international working group created a unified checklist for the publication of randomised trials in medical journals; this is CONSORT, which has been updated several times since, most recently, as of the book's publication, in 2010. According to the author, the use of such lists has improved the quality and uniformity of trial reports, and one important tool for reducing bias is that a publication should be produced for every trial that is started 1.

For AI-based interventions, the list needed expansion because the intervention here is a piece of software, whose version, input, and relationship to the human user are also part of the effect. Xiaoxuan Liu and colleagues published the guideline Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension in 2020, which was developed together with its counterpart for trial protocols, SPIRIT-AI. The authors compiled 29 candidate items from a literature review and expert consultation; these were evaluated by 103 stakeholders in a two-stage Delphi survey, finalised by 31 participants at a consensus meeting, and 34 individuals took part in the pilot use. The result was 14 new items added to the CONSORT 2010 items: the trial report should describe the AI intervention, the instructions and skills required for its use, the care setting into which it is integrated, the handling of input and output data, and the interaction between human and system, and it should analyse error cases 2.

Few and narrow measurements address adherence to the guideline. In 2026, T. Strasser and colleagues reviewed orthopaedic AI trials published since the extension appeared: of 174 publications found, 11 met their criteria, and these fulfilled on average about 11.4 of the extension's items. The usual trial data and the general description of the AI were reported well, while data transparency, handling of data quality, and code accessibility were reported poorly 3. The sample is small and comes from a single specialty, yet the gaps fall precisely on the points for which the extension was created.

External validation as the test of a predictive model

For predictive models, the benchmark for study reporting is TRIPOD+AI, the 2024 guideline by Gary S. Collins and colleagues, which provides updated guidance for reporting clinical prediction models developed using regression and machine learning methods 4. An overview of adherence is provided by the 2026 systematic review by R. H. Kuijten and colleagues. The authors identified 433 studies using machine learning to predict the outcomes of orthopaedic surgery and measured the completeness of reporting in 93 studies published in the 25 highest-impact orthopaedic journals. In 27 per cent of the model-development studies, the sample size raised serious concerns; 36 per cent reported calibration, that is, how closely the estimated risk matches the frequency actually observed; and 13 per cent made the model available. The median completeness according to TRIPOD+AI was 45 per cent 5.

To me, these proportions make one of the points from the second part tangible. Accuracy measured on an independent sample counts as evidence only if the model is available, its calibration is known, and enough patients' data were available for its development. Where these are missing, external validation cannot even begin, because there is nothing to test. The case of the sepsis prediction model discussed in the third part shows the reverse situation: there, the model was already in wide use, and researchers at a health system measured it on their own patients, with a result considerably weaker than on the developer's data 6.

In the era of language models, part of validation takes place via question sets. The 2024 preprint by Soroosh Tayebi Arasteh and colleagues, RadioRAG: Online Retrieval-augmented Generation for Radiology Question Answering, presents a system that searches radiology online sources for supplementary information while answering questions. The authors measured the accuracy of the models on 80 questions drawn from a radiology case collection and 24 questions compiled by experts, finding improvement in most models, with the relative increase reaching up to 54 per cent in some models, while one model showed no improvement 7. Such a measurement characterises the system's knowledge on a fixed set of questions and says nothing about its role in clinical work.

The rule of decision support: when the system may speak

In clinical decision support, one practical direction is the pre-specification of system behaviour. Francisco José Gárate and colleagues' 2026 preprint, A Governance and Evaluation Framework for Deterministic, Rule-Based Clinical Decision Support in Empiric Antibiotic Prescribing, outlines a governance and evaluation framework to support antibiotic selection initiated without knowledge of the pathogen. The framework separates clinical decision logic from the rules that determine whether the system can issue a recommendation at all, treating the refusal to respond as a correct, intended outcome if conditions are not met. Deterministic operation means that identical inputs yield identical outputs, which the authors argue serves transparency and retrospective verifiability. The evaluation, conducted on fixed, artificially constructed cases, examines whether the system behaves according to the defined rules, and the authors state that this test does not measure clinical effectiveness, accuracy, or improvement in outcomes 8.

This practice offers an organisational response to the automation bias discussed in the first part: if the system only activates under specific conditions, there are fewer opportunities to rely on the machine where the machine is uncertain. However, the type of evidence is different from that of a randomised trial. The behavioural test confirms that the system does what the specification requires; whether the specification is good for the patient is revealed only by measuring its use.

Radiology: the most authorisations and slow reorganisation

Radiology is the field where most authorised AI devices are concentrated. According to a report from the 2025 congress of the Radiological Society of North America, FDA experts said in a session that the agency's public list included 1,247 AI-based devices in July, and one of the agency's radiology directors stated that more than 75 per cent of these are radiological, including image segmentation and quantitative measurement devices 9.

It is difficult to infer the transformation of the profession from the number of authorisations. Ajay Agrawal, Joshua Gans and Avi Goldfarb's book Power and Prediction recalls Geoffrey Hinton's prediction from a few years earlier, according to which deep learning would surpass radiologists within five years, and therefore their training should be halted. The authors note that five years later, data from the American College of Radiology showed no decline in the number of individuals entering radiology training. Their explanation is that some AI applications are simple substitutions, replacing an older predictive procedure, while other applications require the redesign of the product or service and the organisation providing it, which is slower 10.

The largest-scale practice for measuring the impact of radiological AI is the trial embedded in screening programmes. According to an announcement of 22 September 2025 by England's health ministry, a trial funded by the national research fund is testing, in the breast screening of nearly 700,000 women, whether AI tools can identify tissue changes suggestive of cancer and, if necessary, refer the women for further examination; the announcement adds that nearly 6 million pounds of government funding is allocated to a national platform connected to all hospital organisations 11. The announcement concerns the launch of the trial, reports no results yet, and does not detail the trial design.

Documentation and patient pathway: the new task of coordination

Language models enter radiology and clinical documentation on the text side. Christian Bluethgen and colleagues' 2024 preprint, Best Practices for Large Language Models in Radiology, starts from the premise that the precise use of language lies at the heart of radiological work, from handling requests through describing findings to communicating results, and that general-purpose language models perform well in professional language tasks without specific training; the review also addresses limitations and the management of model-specific characteristics 12. In documentation systems, the question of evidence is tied to text quality: what is omitted, what is added, and who approves the final note. The approving clinician here finds themselves in the same situation as the user of decision support, and the time pressure bearing down on them similarly pushes towards reliance on the machine.

Sangeet Paul Choudary's book Reshuffle describes the same phenomenon from the perspective of the patient pathway. In his view, the nurse navigator role emerged because digitalised workflows and automated appointment scheduling accelerated individual steps while fragmenting responsibility for the entire patient pathway; alongside specialists optimising their own areas, someone had to ensure the treatment pathway remained coherent. As hospitals introduce AI tools for radiology, diagnostics and patient monitoring, this role ensures that the results of machine analysis trigger the appropriate follow-up 13. In this description, AI accelerates steps individually, while coordination between steps remains human work, and from an evidence perspective, this gap is precisely the critical one: an accurate alert that fails to reach the next step does not alter patient care.

Post-market surveillance

Post-market surveillance originates from the world of pharmaceuticals. According to Leon Gordis's textbook Epidemiology, some side effects only appear after years, or are so rare that even relatively large randomised trials fail to detect them; therefore, phase IV studies follow drugs once they come into widespread use. These are not randomised trials and in fact are not even experiments; their validity requires a very high-quality adverse event reporting system, and alongside side effects, they can provide further evidence of benefit 14.

For AI devices, the same practice also has to reckon with changes to the model. The 2024 FDA guidance mentioned in the third part treats the predetermined change control plan as part of the marketing submission 15. In EU regulation, the regulations on medical devices and on artificial intelligence together require manufacturers to conduct post-market surveillance: the regular collection and analysis of performance and safety data, reporting of adverse events, and corrective actions. According to the joint guidance, the AI Act adds two new elements to this: where necessary, monitoring of interaction with other AI systems and devices, and a requirement that the deployer, for example a hospital, track the system's operation and inform the manufacturer if necessary 16. In the pharmaceutical field, the ten principles published by the EMA and the FDA on 14 January 2026 also extend to safety monitoring 17. The European pharmaceutical industry association's summary, based on case studies, describes the practice from the companies' perspective: continuous monitoring of performance drift after deployment, scheduled re-validation, and inspection-ready documentation; among the main risks are performance degradation and the lack of version control 18. This is the association's description of its members' practice, and it is not backed by any independent survey.

Measurement is decided at the point of use

The profession's toolkit gradually brings measurement closer to the point of use. The checklist makes the description of a study comparable, external validation takes the model to new patients, the behavioural rule makes the machine's output conditional, and post-market surveillance turns real-world use into a data source. Each strengthens one link in the chain, and each closes one of the institutional gaps described in Part 3.

However, measured adherence falls short of the guidelines everywhere. A significant portion of reporting-checklist items is missing from publications, only a small fraction of models is accessible, fewer than half of the studies report calibration, and the results of the largest-scale radiological trials are not yet known. I see the main tension in these practices here: the benchmarks were set at the developer's and the journal's end, yet the test would have to be passed in the hospital. The EU rule, which also obliges the deployer to monitor operation, is a turning point from this perspective, because it makes local measurement a legal condition of deployment. Hospital surveillance provides evidence equivalent to a trial report only if it is produced with the same methodological discipline: with fixed metrics, results tied to a specific version, and analysis of error cases.

Evidence belongs to one decision and one place

The starting point of the series was that the history of medical evidence is the search for the location of error, and this question took a different form in each part: for thinkers, as one point in the chain; for theories, as the addressee of evidence; for actors, as an institutional gap; and for practices, as the place of measurement. The common lesson is that a number about a medical AI always belongs to a specific decision, a specific patient group, and a specific version of the system, and if any of these changes, the validity of the number is again in question. The machine shifts the error within the chain, and evidence keeps pace only if measurement follows the system even after it is placed on the market, all the way to the point where a decision is made about a patient.

Recommended reading

Sources

  1. [1] Trisha Greenhalgh (2014): How to Read a Paper: The Basics of Evidence-Based Medicine (5th edition). book
  2. [2] Nature Medicine, 26, 1364–1374 (2020): Xiaoxuan Liu et al.: Reporting guidelines for clinical trial reports for interventions involving artificial intelligence: the CONSORT-AI extension. Nature Medicine, 26, 1364–1374.
  3. [3] The Journal of Bone and Joint Surgery, American Volume (2026): T. Strasser et al.: Compliance with the CONSORT AI Extension in Orthopaedic Randomized Controlled Trials. The Journal of Bone and Joint Surgery, American Volume.
  4. [4] BMJ, 385, e078378 (2024): Gary S. Collins et al.: TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ, 385, e078378.
  5. [5] Journal of Clinical Epidemiology (2026): R. H. Kuijten et al.: Incomplete reporting persists in orthopedic machine learning models: a systematic review of TRIPOD and TRIPOD+AI reporting completeness. Journal of Clinical Epidemiology.
  6. [6] JAMA Internal Medicine, 181(8), 1065–1070 (2021): Andrew Wong et al.: External Validation of a Widely Implemented Proprietary Sepsis Prediction Model in Hospitalized Patients. JAMA Internal Medicine, 181(8), 1065–1070.
  7. [7] Soroosh Tayebi Arasteh, Mahshad Lotfinia, Keno Bressem, Robert Siepmann et al. (2024): RadioRAG: Online Retrieval-augmented Generation for Radiology Question Answering. arXiv. preprint, not yet peer-reviewed
  8. [8] Francisco José Gárate, Paloma Chausa, Diego Moreno, Judit López Luque et al. (2026): A Governance and Evaluation Framework for Deterministic, Rule-Based Clinical Decision Support in Empiric Antibiotic Prescribing. arXiv. preprint, not yet peer-reviewed
  9. [9] dailybulletin.rsna.org: FDA Outlines Regulatory Pathways and Emerging Challenges for AI-Enabled Radiology Devices. dailybulletin.rsna.org.
  10. [10] Ajay Agrawal, Joshua Gans, Avi Goldfarb (2022): Power and Prediction: The Disruptive Economics of Artificial Intelligence. book
  11. [11] Department of Health and Social Care (2025): AI to be trialled at unprecedented scale across NHS screening. Department of Health and Social Care.
  12. [12] Christian Bluethgen, Dave Van Veen, Cyril Zakka, Katherine Link et al. (2024): Best Practices for Large Language Models in Radiology. arXiv. preprint, not yet peer-reviewed
  13. [13] Sangeet Paul Choudary (2025): Reshuffle: Who Wins When AI Restacks the Knowledge Economy. book
  14. [14] Leon Gordis (1996): Epidemiology. book
  15. [15] U.S. Food and Drug Administration (2024): FDA Roundup: December 3, 2024 (final guidance on predetermined change control plans for AI-enabled device software functions). U.S. Food and Drug Administration.
  16. [16] Artificial Intelligence Board, Medical Device Coordination Group (2025): AIB 2025-1 / MDCG 2025-6: Interplay between the MDR & IVDR and the Artificial Intelligence Act. Artificial Intelligence Board, Medical Device Coordination Group.
  17. [17] European Medicines Agency (2026): EMA and FDA set common principles for AI in medicine development. European Medicines Agency.
  18. [18] efpia.eu: AI Across the Medicines Lifecycle. efpia.eu.

Essays and reviews →

Weekly email

One email a week with the main stories from the Agent Age editions. You confirm by email and can unsubscribe in one click.

Almost done: we sent you an email. Open it and press the confirm link. If it does not arrive within a few minutes, check your spam folder.

↑